Testing for Continuity
Special Tools EL-39200-B Digital Multimeter (DMM) For equivalent regional tools, refer to Special Tools. Danger: This procedure should not be performed on high voltage circuits. Performing this procedure on high voltage circuits may result in serious injury or death.
- Set the DMM to the Ω position.
- Disconnect the power feed (i.e. fuse, control module) from the suspect circuit.
- Disconnect the load.
- Select the MIN MAX function on the DMM.
- Connect one lead of the DMM to one end of the circuit to be tested.
- Connect the other lead of the DMM to the other end of the circuit.
- If the DMM displays low or no resistance, the circuit has good continuity. With a Test Lamp
- Remove the power feed (i.e. fuse, control module) from the suspect circuit.
- Disconnect the load.
- Connect one lead of the test lamp to one end of the circuit to be tested.
- Connect the other lead of the test lamp to battery positive voltage.
- Connect the other end of the circuit to ground.
- If the test lamp illuminates (full intensity), then the circuit has good continuity.