Temperature Valve Actuator Replacement - Left Side
Removal Procedure

- Instrument Panel Lower Insulator Retainer (1) » Remove [2x]

- Instrument Panel Lower Trim Panel Insulator - Left Side (1) » Remove

- Front Floor Console Lower Applique (1) » Remove

- Front Floor Console Extension Panel Bolt Access Hole Cover (1) » Remove
- Front Floor Console Extension Bolt (2) » Remove
- Position the front seat rearward to access the retainers.
- Front Floor Console Extension Panel - Left Side (3) » Remove

-
Heater and Air Conditioning Evaporator and Blower Module Bolt (1) » Remove [2x]
-
Temperature Valve Actuator - Left Side (2) » Remove
-
Disconnect the electrical connector. Installation Procedure
-
Connect the electrical connector.
-
Temperature Valve Actuator - Left Side (2) » Install
-
Heater and Air Conditioning Evaporator and Blower Module Bolt (1) » Install and tighten [2x] — Fastener Specifications
-
Front Floor Console Extension Panel - Left Side (3) » Install
-
Front Floor Console Extension Bolt (2) » Install and tighten — Fastener Specifications
-
Front Floor Console Extension Panel Bolt Access Hole Cover (1) » Install
-
Front Floor Console Lower Applique (1) » Install
-
Instrument Panel Lower Trim Panel Insulator - Left Side (1) » Install
-
Instrument Panel Lower Insulator Retainer (1) » Install [2x]