Master Electrical Schematic Icons

Wiring Systems and Power Management | Schematic and Routing Diagrams | Document ID: 4371902

Icon Icon Definition
Warning: When performing service on or near the SIR components or the SIR wiring, the SIR system must be disabled. Refer to SIR Disabling and Enabling . Failure to observe the correct procedure could cause deployment of the SIR components, personal injury, or unnecessary SIR system repairs.
Note: Twisted-pair wires provide an effective shield that helps protect sensitive electronic components from electrical interference. If the wires were covered with shielding, install new shielding. In order to prevent electrical interference from degrading the performance of the connected components, you must maintain the proper specification when making any repairs to the twisted-pair wires shown : The wires must be twisted a minimum of 9 turns per 31 cm (12 in) as measured anywhere along the length of the wires. The outside diameter of the twisted wires must not exceed 6.0 mm (0.25 in).
Master Electrical Schematic Icons — figure 1
Master Electrical Schematic Icons — figure 1